genset control
易根3000XT
Woodward raised the standard in genset paralleling control and power management system with the easYgen-3000XT Series controllers. These controllers come with standardized software that is simple to configure, yet easily customized for individual applications. Enhanced connectivity enables fast, reliable and secure interfac-ing to other controls and communications systems while the enhanced hardware is a drop-in replacement for previous generation easYgen-3000 Series Controls.
Targeted at enabling complex power management applications, the easYgen-3500XT supports easYgen | GC-3000XT to manage a large genset fleet of up to 496 sets and easYgen | LS-6XT to control up to 64 synchroniz-ing breaker or manual switches on up to 128 complex bus segments. Redundant load sharing is selectable us-ing Ethernet B and C networks for enhanced reliability. The control combines complete engine-generator con-trol and protection with advanced, peer-to-peer paralleling functionality and innovative features in a robust, at-tractive, user-friendly and all-in-one package. The easYgen-3500 XT controls are designed to direct connect up to 690Vac and operate to 4000m above sea level without derating.
The easYgen-3500XT is available in two packages. P1, focused at complex paralleling applications provides redundant Ethernet communication, LS-5 connectivity, and standard I/O set, while P2, Co-Gen/CHP model offers expanded onboard I/O set, 3-ph busbar voltage measurement capability and phase rotation monitoring between gen-busbar and busbar-utility. These packages are available without a display in a rugged metal hous-ing suitable for back panel installations (easYgen-3400XT-P1 and easYgen-3400XT-P2 respectively). A sophis-ticated touch screen remote panel (RP-3000XT) complements them as an operator control panel. A version of easYgen-3500XT (easYgen-3500XT-P1-LT and easYgen-3500XT-P2-LT) is designed to operate down to -400 C for outdoor applications.
选项
3100 XT 精简版 | 3100 XT | 3400 XT 包 1 | 3400 XT 包 2 | |
---|---|---|---|---|
同步 | ||||
发电机断路器 | ||||
电源断路器 | ||||
发电机组断路器 | ||||
跑起来/黑启动 | ||||
保护 | ||||
发电机 | ||||
引擎 | ||||
电源 | ||||
硬件 | ||||
CANBus 端口 | 2 | 2 | 3 | 3 |
RS485 | ||||
以太网 Modbus TCP 端口 | 1 | 1 | 3 | 3 |
可自由配置的 PID(例如速度和电压偏置) | 3 | 3 | 3 | 3 |
母线感应,电源感应 | ||||
690 VAC 感应 | ||||
电源电流感应 | ||||
母线电压感应 | 2相 | 2相 | 三相 | |
数字输入 | 12 | 12 | 12 | 23 |
数字输出 | 12 | 12 | 12 | 22 |
模拟输入 | 3 | 3 | 3 | 10 |
模拟输出 | 2 | 2 | 2 | 6 |
kWh 和 kVArh 的 PWM 输出 | ||||
职能 | ||||
通过 CAN 和/或以太网进行负载共享 | ||||
通过以太网和/或 CANopen 进行冗余负载共享 | ||||
支持组控制器 LS-5 和 LS-6XT | ||||
负载相关的启停 | ||||
进出口管制 | ||||
PV (photovoltaic) control | ||||
AVR integral voltage regulation (with exciter-10) | *upgrade available | *upgrade available | ||
租赁功能:四个可切换的参数集,用于计费的附加计数器,...... | ||||
工作温度 | -40°C 至 +70°C | -40°C 至 +70°C | -40°C 至 +70°C | -40°C 至 +70°C |
零件号 | 8440-2280 | 8440-2081 | 8440-2084 | 8440-2087 |
产品规格 | 产品规格 | 产品规格 |
3100 XT 套餐 1 租赁 | 3400 XT 套餐 1 租赁 | 3400 XT 包 2 租赁 | |
---|---|---|---|
同步 | |||
发电机断路器 | |||
电源断路器 | |||
发电机组断路器 | |||
跑起来/黑启动 | |||
保护 | |||
发电机 | |||
引擎 | |||
电源 | |||
硬件 | |||
CANBus 端口 | 2 | 3 | 3 |
RS485 | |||
以太网 Modbus TCP 端口 | 1 | 3 | 3 |
可自由配置的 PID(例如速度和电压偏置) | 3 | 3 | 3 |
母线感应,电源感应 | |||
690 VAC 感应 | |||
电源电流感应 | |||
母线电压感应 | 2相 | 2相 | 三相 |
数字输入 | 12 | 12 | 23 |
数字输出 | 12 | 12 | 22 |
模拟输入 | 3 | 3 | 10 |
模拟输出 | 2 | 2 | 6 |
kWh 和 kVArh 的 PWM 输出 | |||
职能 | |||
通过 CAN 和/或以太网进行负载共享 | |||
通过以太网和/或 CANopen 进行冗余负载共享 | |||
支持组控制器 LS-5 和 LS-6XT | |||
负载相关的启停 | |||
进出口管制 | |||
PV (photovoltaic) control | |||
AVR integral voltage regulation (with exciter-10) | *upgrade available | ||
租赁功能:四个可切换的参数集,用于计费的附加计数器,...... | |||
工作温度 | -40°C 至 +70°C | -40°C 至 +70°C | -40°C 至 +70°C |
零件号 | 8440-2284 | 8440-2287 | 8440-2289 |
选项
3200 XT 精简版 | 3200 XT | 3500 XT 包 1 | 3500 XT 包 2 | |
---|---|---|---|---|
同步 | ||||
发电机断路器 | ||||
电源断路器 | ||||
发电机组断路器 | ||||
跑起来/黑启动 | ||||
保护 | ||||
发电机 | ||||
引擎 | ||||
电源 | ||||
硬件 | ||||
CANBus 端口 | 2 | 2 | 3 | 3 |
RS485 | ||||
以太网 Modbus TCP 端口 | 1 | 1 | 3 | 3 |
可自由配置的 PID(例如速度和电压偏置) | 3 | 3 | 3 | 3 |
母线感应,电源感应 | ||||
690 VAC 感应 | ||||
电源电流感应 | ||||
母线电压感应 | 2相 | 2相 | 三相 | |
数字输入 | 12 | 12 | 12 | 23 |
数字输出 | 12 | 12 | 12 | 22 |
模拟输入 | 3 | 3 | 3 | 10 |
模拟输出 | 2 | 2 | 2 | 6 |
kWh 和 kVArh 的 PWM 输出 | ||||
职能 | ||||
通过 CAN 和/或以太网进行负载共享 | ||||
通过以太网和/或 CANopen 进行冗余负载共享 | ||||
支持组控制器 LS-5 和 LS-6XT | ||||
负载相关的启停 | ||||
进出口管制 | ||||
PV (photovoltaic) control | ||||
AVR integral voltage regulation (with exciter-10) | *upgrade available | *upgrade available | ||
租赁功能:四个可切换的参数集,用于计费的附加计数器,...... | ||||
工作温度 | -20 °C 至 70 °C | -20 °C 至 70 °C | -20 °C 至 70 °C | -20 °C 至 70 °C |
零件号 | 8440-2281 | 8440-2082 | 8440-2085 | 8440-2088 |
产品规格 | 产品规格 | 产品规格 |
3200 XT LT 精简版 | 3200 XT LT | 3500 XT 包装 1 LT | 3500 XT 包 2 LT | |
---|---|---|---|---|
同步 | ||||
发电机断路器 | ||||
电源断路器 | ||||
发电机组断路器 | ||||
跑起来/黑启动 | ||||
保护 | ||||
发电机 | ||||
引擎 | ||||
电源 | ||||
硬件 | ||||
CANBus 端口 | 2 | 2 | 3 | 3 |
RS485 | ||||
以太网 Modbus TCP 端口 | 1 | 1 | 3 | 3 |
可自由配置的 PID(例如速度和电压偏置) | 3 | 3 | 3 | 3 |
母线感应,电源感应 | ||||
690 VAC 感应 | ||||
电源电流感应 | ||||
母线电压感应 | 2相 | 2相 | 三相 | |
数字输入 | 12 | 12 | 12 | 23 |
数字输出 | 12 | 12 | 12 | 22 |
模拟输入 | 3 | 3 | 3 | 10 |
模拟输出 | 2 | 2 | 2 | 6 |
kWh 和 kVArh 的 PWM 输出 | ||||
职能 | ||||
通过 CAN 和/或以太网进行负载共享 | ||||
通过以太网和/或 CANopen 进行冗余负载共享 | ||||
支持组控制器 LS-5 和 LS-6XT | ||||
负载相关的启停 | ||||
进出口管制 | ||||
PV (photovoltaic) control | ||||
AVR integral voltage regulation (with exciter-10) | *upgrade available | *upgrade available | ||
租赁功能:四个可切换的参数集,用于计费的附加计数器,...... | ||||
工作温度 | -40°C 至 +70°C | -40°C 至 +70°C | -40°C 至 +70°C | -40°C 至 +70°C |
零件号 | 8440-2272 | 8440-2083 | 8440-2086 | 8440-2089 |
产品规格 | 产品规格 | 产品规格 |
3200 XT 套餐 1 租赁 | 3500 XT 套餐 1 租赁 | 3500XT 套餐 2 租赁 | |
---|---|---|---|
同步 | |||
发电机断路器 | |||
电源断路器 | |||
发电机组断路器 | |||
跑起来/黑启动 | |||
保护 | |||
发电机 | |||
引擎 | |||
电源 | |||
硬件 | |||
CANBus 端口 | 2 | 3 | 3 |
RS485 | |||
以太网 Modbus TCP 端口 | 1 | 3 | 3 |
可自由配置的 PID(例如速度和电压偏置) | 3 | 3 | 3 |
母线感应,电源感应 | |||
690 VAC 感应 | |||
电源电流感应 | |||
母线电压感应 | 2相 | 2相 | 三相 |
数字输入 | 12 | 12 | 23 |
数字输出 | 12 | 12 | 22 |
模拟输入 | 3 | 3 | 10 |
模拟输出 | 2 | 2 | 6 |
kWh 和 kVArh 的 PWM 输出 | |||
职能 | |||
通过 CAN 和/或以太网进行负载共享 | |||
通过以太网和/或 CANopen 进行冗余负载共享 | |||
支持组控制器 LS-5 和 LS-6XT | |||
负载相关的启停 | |||
进出口管制 | |||
PV (photovoltaic) control | |||
AVR integral voltage regulation (with exciter-10) | *upgrade available | ||
租赁功能:四个可切换的参数集,用于计费的附加计数器,...... | |||
工作温度 | -20 °C 至 70 °C | -20 °C 至 70 °C | -20 °C 至 70 °C |
零件号 | 8440-2285 | 8440-2283 | 8440-2290 |
3200XT 套餐 1 LT 租赁 | 3500 XT 套餐 1 LT 租赁 | 3500XT 包 2 LT 租赁 | |
---|---|---|---|
同步 | |||
发电机断路器 | |||
电源断路器 | |||
发电机组断路器 | |||
跑起来/黑启动 | |||
保护 | |||
发电机 | |||
引擎 | |||
电源 | |||
硬件 | |||
CANBus 端口 | 2 | 3 | 3 |
RS485 | |||
以太网 Modbus TCP 端口 | 1 | 3 | 3 |
可自由配置的 PID(例如速度和电压偏置) | 3 | 3 | 3 |
母线感应,电源感应 | |||
690 VAC 感应 | |||
电源电流感应 | |||
母线电压感应 | 2相 | 2相 | 三相 |
数字输入 | 12 | 12 | 23 |
数字输出 | 12 | 12 | 22 |
模拟输入 | 3 | 3 | 10 |
模拟输出 | 2 | 2 | 6 |
kWh 和 kVArh 的 PWM 输出 | |||
职能 | |||
通过 CAN 和/或以太网进行负载共享 | |||
通过以太网和/或 CANopen 进行冗余负载共享 | |||
支持组控制器 LS-5 和 LS-6XT | |||
负载相关的启停 | |||
进出口管制 | |||
PV (photovoltaic) control | |||
AVR integral voltage regulation (with exciter-10) | *upgrade available | ||
租赁功能:四个可切换的参数集,用于计费的附加计数器,...... | |||
工作温度 | -40°C 至 +70°C | -40°C 至 +70°C | -40°C 至 +70°C |
零件号 | 8440-2286 | 8440-2288 | 8440-2291 |