function ChangeDisplay() { var fSwitchOn = document.getElementById("firstSliderOn"); var fSwitchOff = document.getElementById("firstSliderOff"); var sSwitchOn = document.getElementById("secondSliderOn"); var sSwitchOff = document.getElementById("secondSliderOff"); var imgOn = document.getElementById("firstDisplayON"); var imgOff = document.getElementById("firstDisplayOFF"); var tableOne = document.getElementById("tableOne"); var tableTwo = document.getElementById("tableTwo"); var tableThree = document.getElementById("tableThree"); var buttonsOneTable = document.getElementById("buttonsOneTable"); var buttonsTwoTable = document.getElementById("buttonsTwoTable"); var buttonsThreeTable = document.getElementById("buttonsThreeTable"); var fDisplayOnText = document.getElementById("firstDisplayONText"); var rp3000xtSection = document.getElementById("rp3000xtSection"); if(fSwitchOn.style.display === "none") { fSwitchOn.style.display = "block"; fSwitchOff.style.display = "none"; sSwitchOn.style.display = "none"; sSwitchOff.style.display = "block"; imgOn.style.display = "block"; imgOff.style.display = "none"; tableOne.style.display = "none"; tableTwo.style.display = "block"; tableThree.style.display = "none"; buttonsOneTable.style.display = "none"; buttonsTwoTable.style.display = "block"; buttonsThreeTable.style.display = "none"; rp3000xtSection.style.display = "none"; fDisplayOnText.style.display = "block"; } else { fSwitchOn.style.display = "none"; fSwitchOff.style.display = "block"; sSwitchOn.style.display = "none"; sSwitchOff.style.display = "none"; imgOn.style.display = "none"; imgOff.style.display = "block"; tableOne.style.display = "block"; tableTwo.style.display = "none"; tableThree.style.display = "none"; buttonsOneTable.style.display = "block"; buttonsTwoTable.style.display = "none"; buttonsThreeTable.style.display = "none"; rp3000xtSection.style.display = "flex"; fDisplayOnText.style.display = "none"; } }
function ChangeSecondDisplay() { var sSwitchOn = document.getElementById("secondSliderOn"); var sSwitchOff = document.getElementById("secondSliderOff"); var tableOne = document.getElementById("tableOne"); var tableTwo = document.getElementById("tableTwo"); var tableThree = document.getElementById("tableThree"); var buttonsOneTable = document.getElementById("buttonsOneTable"); var buttonsTwoTable = document.getElementById("buttonsTwoTable"); var buttonsThreeTable = document.getElementById("buttonsThreeTable"); if(sSwitchOn.style.display === "none") { sSwitchOn.style.display = "block"; sSwitchOff.style.display = "none"; tableOne.style.display = "none"; tableTwo.style.display = "none"; tableThree.style.display = "block"; buttonsOneTable.style.display = "none"; buttonsTwoTable.style.display = "none"; buttonsThreeTable.style.display = "block"; } else { sSwitchOn.style.display = "none"; sSwitchOff.style.display = "block"; tableOne.style.display = "none"; tableTwo.style.display = "block"; tableThree.style.display = "none"; buttonsOneTable.style.display = "none"; buttonsTwoTable.style.display = "block"; buttonsThreeTable.style.display = "none"; } }
Synchronizer

Synchronizer device

Synchronizer device, frequenz-, phasen- und spannungsanpassung usw.

Synchronizer

SPM-D2 10SPM-D2 11
breakers synchronized1 or 21
AC phases2 or 33
frequency, phase and voltage matching
active power (kW) / reactive power (VAR) sharing (analog)
Active power and power factor control
Analog input to control active power set-point externally
generator protection
selectable control outputs for speed and voltage biasing
compatible with a wide range of govenors and voltage regulators
circuit breaker time compensation
configuration via HMI or PC
password protection
product specificationproduct specification

Synchronizers for 2/3-phase AC Gen-Sets - SPM-D2

Woodward understands the time-intensive nature of Power Generation projects. Ensuring the lon-gevity of components is one way we can make our customers successful. Woodward has supplied and supported the well-established SPM-D line of synchronizers for 20+ years. With the state of the art Drop-In replacement successor, SPM-D2 the life of this synchronizer line is now extended. All of the SPM-D2 synchronizers are password protected and are configurable either through HMI as before or through ToolKit configuration tool with USB connectivity.
The SPM-D2-10 series are microprocessor-based synchronizers designed for use on two or three phase AC generators equipped with Woodward or other compatible speed controls and automatic voltage regulators. The SPM-D2-10 synchronizers provide automatic frequency, phase and voltage matching using either analog- or discrete output bias signals. These synchronizers are applied to a wide range of prime movers and generators, as its control signals may be set to fit several types of gensets – from fast reacting diesel engines to soft reacting gas turbines.

Accessories

Configuration Software

Toolkit

Pramertization via Woodward’s standard Software Toolkit.

USB Mini

USB Mini-Type B to Type A

Market standard USB Mini-Type B to Type A cable to connect to the PC/laptop.

 

This is a standard electronic item, not available at Woodward.

BackPack Mounting

Back-Panel mounting option

This adapter enables you to mount the relays inside cabinets

 

Din Rail mounting adapter

part number: 8923-1023

 

USB Mini

Gaskets for a front panel mounting

Front panel mounting comes with IP42; to increase to IP54 a gasket is required.

 

part number: 8923-1037

en_USEnglish